Elevator Control

Overview

EvTrack combined with 2N and Axis IP Hardware creates a ‘multi-zone’ or multi-floor elevator access control solution. A single reader can be programmed with different credentials which are linked to one or more output relays. An elevator with up to 40 ‘Floors’ can be supported.

  • IP RFID Reader or IP Keypad with Integrated Controller & Edge Credential Storage.
  • IP 8-Way Relay Output Board (Can be Cascaded for Buildings with +8 Floors).
  • Control Access to Individual Floors by Credential and By Holder
  • Configurable Access Control Door Groups.
  • Configurable Access Control Time Schedules.
  • Full integration with Handheld Visitor Scanning For Creation of Temporary Credentials.
  • Creation of Temporary Access Control Pin Codes or QR Codes for Visitor Access.

Configuration

  1. License 2N Controller
  2. Navigate to Configuration > Access Control Settings > Elevator and Add/Remove the elevator floors of the building.
  3. Configure Device Elevator Support. Navigate to Configuration > Devices, Select the target device and click on the "Elevator" tab:
  4. Create Access Control List Rules to permit access to Floors.
  5. Troubleshooting

Step 1: Install 2N Lift Control Support License

Step 2: Navigate to Configuration > Access Control Settings > Elevator and Add/Remove the elevator floors of the building.

Step 3: Configure Device Elevator Support. Navigate to Configuration > Devices, Select the target device and click on the "Elevator" tab:

Step 3.1: Set the Administrator (root) / Password for the the Axis A9188 Relay Modules.
Step 3.2: Configure and Enabled the A9188 Relay Modules (Please note to use the Internal/Private IP Addresses)

Step 3.3: Assign Floors configured in step 2 to Relay Outputs

Step 4. Create Access Control List Rules to permit access to Floors.

Step 4.1: Navigate to Configuration > Access Control Settings > Access Control List:

Step 4.2: Add / Delete Elevator Rules (Select the floor and shedule)

Step 5: Troubleshooting

Step 5.1: Confirm that the A9188 relay modules are online and authenticated.